名称:Single stage volute pump

介绍(Introduce):

Single-stage volute pump, performance in accordance with EN 733, with replaceable shaft sleeve and casing seals, with motor speed control system. Use with synchronous reluctance motors without magnets of efficiency class IE4/IE5 (according to IEC TS 60034-30-2:2016) (Exception: Pump size 0.55 kW/0.75 kW at 1500 rpm with permanent magnets). Mounting points in accordance with EN 50347, housing dimensions in accordance with DIN V 42673 (07-2011). ATEX-compatible version available as an option.

主要应用(Main applications):

1. Transport of colorless or corrosive liquids that do not chemically or mechanically attack the pump material

2. Water supply systems

3. Cooling circuits

4. Swimming pool equipment

5. Fire protection systems

6. Irrigation equipment

7. Drainage equipment

8. Heating equipment

9. Air conditioning equipment

10. Sprinkler equipment

技术数据(Technical Data):

Component Function

Delivery

Inlet connection method

Flange

Drive scheme

With E drive, turbine

Highest generation series flow

755 m3/h

min.Generation Series Flow

1 m3/h

The highest generation series lift

160 m

min. series lift

1 m

Power frequency

50 Hz,60 Hz

Line Voltage

400 V,
460 V,
220 V,
230 V,
240 V,
380 V,
415 V,
500 V,
575 V,
660 V,
690 V

Housing Material

EN-GJL-250/A48 CL 35B,
CUSN10-C-GS/B30 C90700,
GX5CRNIMO19-11-2/A743 GR CF-8M,
EN-GJS-400-15/A536 GR 60-40-18,
5.1301+KATAPHORESE

Pressure class output

PN 16,
PN 10,
CL 150,
CL 125

Maximum allowable discharge side operating pressure of the series

16 bar

Inhalation characteristics

Non-self-priming

Maximum permissible medium temperature

140 °C

Minimum permissible medium temperature

-30 °C

优势Advantages):

1. Experimentally confirmed hydrodynamic properties of the impeller (blades) improve efficiency and NPSHreq

2. Reduced operating costs due to nominal impeller diameter turned to the operating point

3. Low wear, low vibrations and highly smooth operation due to good suction characteristics and virtually cavitation-free operation over a wide range

4. Multi-chamber housing seal for reliable housing sealing despite varying operating conditions

5. A wide range of standard materials for optimal adaptation to the conveying medium

6. Extended size range for smaller conveying volumes is also possible

7. Easy disassembly due to withdrawal screws at the junction between pump cover and drive bracket


Previous:Horizontal installation/vertical installation volute pump